electrodes

Cell for electrolysis

Jul 21, 2015 

598Cell for electrolysis two electrodes

Suitable for flat specimen dia 30mm thickness 1mm
Max capability 50ml.

Reference Electrodes Series

Nov 14, 2011 

General Purpose Reference Electrodes

Model Description Solution dia
(mm)
lenght
(mm)
303/SCG/6 303Calomel Saturated Kcl refilling solution 6 110
303/SCG/6J 303scg6jCalomel with glass Joint Saturated Kcl refilling solution  6 110
303/SCG/12 303scg12Calomel Saturated Kcl refilling solution  12 120
303/SCG/12J 303scg12jCalomel with glass Joint Saturated Kcl refilling solution 12 120
363/SSG/12 Ag/AgCl (argenthal) 12 120
373/SSG/6 373-SSG-6Ag/AgCl 6mm 3mol/L Kcl refilling solution 6 110
373/SSG/6J 373-SSG-6JAg/AgCl with Joint 3mol/L Kcl refilling solution 6 110
373/SSG/12 373SSG12Ag/AgCl 12mm 3mol/L Kcl refilling solution 12 120
373/SSG/12J 373-SSG-12J_bisAg/AgCl with Joint 3mol/L Kcl refilling solution 12 120
383/SHG/12 383shg12Hg/HgSO4 12mm 0.5mol/L K2SO4 refilling solution  12 120
383/SHG/12J 383-SHG-12-JHg/HgSO4 with Joint Saturated K2SO4  refilling solution 12 120
383/SCU/12 383scu12Cu/CuSO4 12mm Saturated CuSO4  refilling solution 12 120
383/OHG/12 383ohg12Hg/HgO 12 mm 0.1 mol/L KOH  refilling solution 12 120
390/TCG/12 390tcg12Double bridge Calomel internal:
saturated Kcl refilling solution
external:
saturated KNO3 refilling solution
12 120
390/TCG/12J Double bridge CalomelDouble bridge Calomel.
Suitable for use with all SENS-ION Mandatory
internal:
saturated Kcl refilling solution
external:
saturated KNO3 refilling solution
12 120
391/CR 391cr  Adapter

 

Redox Electrodes Series

Oct 22, 2011 

Combined Electrodes for Redox

Model Description dia
(mm)
lenght
(mm)
800/CSG/12 800csg12
Combined Ag/AgCl 12mm dia, 0-80°C
12 120
805/CPG/12 805cpg12
Combined Platinum Ag/AgCl
12 120
805/CPG/12R 805cpg12R
Combined Platinum Ring Ag/AgCl
12 120
391/CR 391CR
Conical Adapter

Metallic Electrodes Series

Oct 22, 2011 

Counter Electrodes

Model Description dia
(mm)
lenght
(mm)
800/SSG/12 Silver 12mm dia, glass body 12 120
805/SPG/12 (*)
805SPG12

Platinum 12mm, glass body

12 120
805/SPG/12R
805spg12R

Platinum Ring 12mm glass body

12 120
805/SPG/6J
805spg6JP

Platinum 6mm with joint NS6

6 120
880/TPG/12J Twin Point Platinum electrode for K.F. tiration with joint 12 120
(*) also available in 6mm dia, in 50mm lenght version and with Joints

 

Solid Electrodes Series

Oct 22, 2011 

Miscellanea Tips

Model Descritpion
493 493 Universal electrode holder for all tips
492 492
492/GC/3 Glassy carbon tip 3mm dia
492/PG/3 Pyrolitic graphite tip 3mm dia
492/CU/3 Copper tip 3mm dia
492/CU/2 Copper tip 2mm dia
492/AG/1 Silver tip 1mm dia
492/AG/3 Silver tip 3mm dia
492/PT/1 Platinum tip 1mm dia
492/PT/2 Platinum tip 2mm dia
492/PT/3 Platinum tip 3mm dia
492/GO/1 Gold tip 1mm dia
492/GO/2 Gold tip 2mm dia
492/NI/3 Nickel tip 3mm dia
492/NI/6 Nickel tip 6mm dia
492/TI/3 Titanium tip 3mm dia
492/TI/6 Titanium tip 6mm dia
492/SP Special tips upon request
492/OR-2007 Replacement O-Ring for all tips


pH Electrodes Series

Oct 21, 2011 

Glass and Combined Electrodes for pH

Model Description dia
(mm)
lenght
(mm)
211/SGG/12 211-SGG-12
Glass 0-14 pH, 0-80°C
12 120
211/SSG/12J 211sgg12j
Glass 0-14 pH, 0-80°C with N12 glass Joint
12 120
411/CGG/6 411cgg6
Combined Glass Ag/AgCl 0-14 pH, 0-80°C
6 110
411/CGG/6J
Combined Glass Ag/AgCl 0-14 pH, 0-80°C with Joint
6 110
411/CGG/12 411cgg12
Combined Glass Ag/AgCl 0-14 pH, 0-80°C
12 120
401/PM3/12 Combined Glass Ag/AgCl with 3-frit 12 120
101L-DGSM Double junction pH electrode with majorated frit 12 120
391/CR 391crConical Adapter

Ion Electrodes Series

Oct 21, 2011 

Standard Range Mono Ion Selective Electrodes

Model Description Concentration Lower
Limit
(ppm)
Temp. Main
interferences
pH ISAB
201/NH4 Ammonium
(NH4+)
1M-10-6M 0,02 0-50 K+=1,2×10-1,
Na+=2,0×10-3,
Mg2+=2,0×10-4
11-13 4MLiAc
201/BA Barium
(Ba2+)
1M-5×10-6M 10 0-50 Na+=4×10-4,
K+=9×10-3,
Ca2+=2,5×10-3
5-9 4MLiAc
201/BR Bromide
(Br)
1M-5×10-6M 0,4 0-80 I, S2-, CNmust
be absent,
OH=3×10-5,
Cl=2.4×10-3
2-12 5M
NaNO3
201/CD Cadmium
(Cd2+)
10-1-10-6M 0,2 0-80 Ag+, Hg2+,
Cu2+<10-7M
3-7 5M
NaNO3
201/CA Calcium
(Ca2+)
1M-5×10-7M 0,02 0-50 Mg2+, Ba2+,
Pb2+, Zn2+, Na+
4-9 4MKCl
201/CL Chloride
(Cl-)
1M-5×10-5M 1,8 0-80 Br, I, CN must
be absent,
S2-must be<10-7M
2-11 5M
NaNO3
201/CU Copper
(Cu2+)
1M-5×10-6M 0,3 0-80 S2-, Ag+, Hg2+
should be absent
Cl, Brinterfere
0-7 5M
NaNO3
201/CN Cyanide
(CN)
10-2-10-6M 0,03 0-80 S2 must be
<10-7M,I=1,0
10-14 5M
NaOH
201/F Fluoride
(F)
1M-5×10-7M 0,01 0-80 OH=10-1 5-8 TISAB
201/I Iodide
(I)
1M-10-7M 0,02 0-80 S2 must be
<10-7M/CN=1,0
3-12 5M
NaNO3
201/PB Lead
(Pb2+)
10-1-5×10-6M 1,0 0-80 S2-, Ag+, Hg2+
should be absent,
Cd2+, Cu2+, Fe3+
interfere
0-9 5M
KNO3
201/NO Nitrate
(NO3)
1M-5×10-6M 0,08 0-50 Cl, NO2, Br, SO42-,
F, ClO3, ClO4
3-10 1M
KH2PO4
201/K Potassium
(K+)
1M-10-6M 0,04 0-50 Na+, Ca2+, Rb+,
Mg2+, Cs+, NH4+
4-9 TEAC
201/AG Silver
(Ag+)
1M-10-7M 0,01 0-80 S2-, Hg2+
must be absent
2-9 5M
NaNO3
201/NA Sodium
(Na+)
Sat.-10-6M 1ppb -5-+70 Li+, K+,
NH4+/Ag should
be absent
9-12 SISAB

Combination Ion Selective Electrodes

Model Description Concentration Lower
Limit
(ppm)
Temp. Main
interferences
pH ISAB
201/NH4/CO Ammonium
(NH4+)
0,5 – 5 x -10-5 9,000-0,9 0-50 K+, Na+ 0-8,5 CH3COOH
201/CA/CO Calcium
(Ca2+)
10-1 – 5 x 10-7 4,010 – 0,02 0-50 Ba++, Al+++, Sr++
3,5-11 KCL
201/CL/CO Chloride
(Cl-)
1 – 3 x 10-6 35,500 – 1 5-50 I+, Br, CN, S 2-11 5M
NaNO3
201/F/CO Fluoride
(F)
10-1 – 1 x 10-6 1,900 – 0,02 5-50 OH 4-8 TISAB
201/NO/CO Nitrate
(NO3)
1 – 7 x 10-6 62,000 – 0,4 0-50 Cl, NO 2-11 4M
(NH4)2SO4
201/K/CO Potassium
(K+)
1 – x 10-6 39,000 – 0,04 0-50 Cs+, NH4+ 1-9 TEAC

By continuing to use the site, you agree to the use of cookies. more information